[ESC+IY] Exclusive Display Start-End
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
The message area (upper and lower column) that is specified by Displayed Messages <IM> is
exclusively used and messages from the printer system will not be displayed temporarily.
[Format]
<IY>a
-
Parameter
a [Exclusive display start-end]
       1 : Start exclusive display
       0 : End exclusive display
[Coding Example 1]
Start exclusive display
<A>
<IY>1
<Z>
[Coding Example 2]
End exclusive display
<A>
<IY>0
<Z>
[Supplementary Explanation]
-
Do not specify this command together with other SBPL commands in the same item.
-
Send this command only when this product is online and operation stop (waiting for receive)
status.
-
The data which this command is included are not received while this product is operating. This
is true for both start/end exclusive display.
-
The icon display area is not possible to use exclusively.
-
This command is invalid when the printer is offline or error state.
-
Error messages are not displayed while the display is used exclusively. Confirm with icons only.
-
The display will not be used exclusively when message display is not specified by Displayed
Messages <IM>.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
IY
<49>
<59>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.