SATO SG112 ex Programming Reference Manual page 23

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+Z] Stop Code
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the end of data transmission.
[Format]
<Z>
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABCD
<Q>2
<Z>
[Supplementary Explanation]
-
Indicates the end of item and to be placed at the tail of item.
-
Use Start Code <A> and Stop Code <Z> as a pair of commands.
[Note]
-
If this command is not specified, printing will not be performed.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
Z
<5A>
16
The set command is not maintained.
The set command becomes invalid.
The set command becomes invalid.