[ESC+A3] Base Reference Point
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Changing the start point coordinate. This is set in "Settings" mode of this product (normally).
[Format]
<A3>VabbbHcddd
-
Parameter
a [Vertical start point correction sign] = +, - (Omissible)
b [Vertical start point correction (Number of dots)] = 0 to 792 (dots)
c [Horizontal start point correction sign] = +, - (Omissible)
d [Horizontal start point correction (Number of dots)] = 0 to 792 (dots)
[Coding Example]
<A>
<A3>V+10H+10
<Z>
d
New start point
[Supplementary Explanation]
-
If changing start point correction and being located outside of printing area, printing may not be
performed.
-
When changing start point correction through multiple label formats, correction will affect all of
the formats.
[Points]
-
This command is effective prior to the "Settings" mode settings of this product.
ESC
<1B>
16
a=+,b=000,c=+,d=000
When the power is OFF
Valid range within items
Valid range between items
Original start point
b
A3
<41>
<33>
16
16
The set parameter is maintained.
The set parameter is valid until the next specification is
made.
The set parameter is valid until the next specification is
made.
307
Parameter
VabbbHcddd