[ESC+*] Memory Card Clear
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Clearing the entire contents in memory card (option).
[Format]
<*>a(,bbb)
-
Parameter
a [Item to be cleared]
G : SATO Graphic
P : PCX file
M : BMP file
F : Format
O : TrueType font
R : Form Overlay
b [Registration No.] = Valid range :
000 to 099 (Omissible) TrueType font
001 to 999 (Omissible) Except TrueType font
(When omitting Registration No., all the registered data will be cleared.)
[Coding Example 1]
Clearing 001 of SATO graphic
<A>
<CC>1
<*>G,001
<Z>
[Coding Example 2]
Clearing 002 of PCX file
<A>
<CC>1
<*>P,002
<Z>
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
(Clearing graphic registered with Registration of Graphic <GI>)
(Clearing PCX file registered with Registration of PCX File <PI>)
(Clearing BMP file registered with Registration of BMP File <GT>)
(Clearing format registered with Registration of Format <YS>)
(Clearing TrueType font registered with Registration of TrueType Font <BJ>)
(Clearing form overlay registered with Registration of Form Overlay <&S>)
*
<2A>
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
356