[ESC+ID] Job ID Number
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying job ID number for status return.
[Format]
<ID>aa
-
Parameter
a [Job ID number]
Valid range: 00 to 99 (fixed as 2 digits)
[Coding Example]
Job ID Number: 01
<A>
<ID>01
<V>200<H>100<P>0<$>B,100,100,6
<$=>SATOPRINTER
<Q>2
<Z>
[Supplementary Explanation]
-
When status return is used for interface protocol, the specified job ID number can be set to the
telegraphic status.
-
Status can be confirmed by sending status request (ENQ).
-
Include this command within items and use between Start Code <A> and Stop Code <Z>.
[Points]
-
In status return interface protocol, this command becomes valid when status request (ENQ) is
received while printing (QTY≠0, includes at the time of Offline and Error).
-
In status return communication protocol, if status request (ENQ) is received when printing is not
in progress (QTY=0, No received data when power is ON), space (20H) will be set to status and
returned.
-
When Job ID Number <ID> is used more than twice within the items of Start Code <A> and
Stop Code <Z>, the last specified value becomes valid.
ESC
<1B>
16
a=<20>
16
When the power is OFF
Valid range within items
Valid range between items
ID
<49>
<44>
16
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter becomes invalid.
24
Parameter
aa