[ESC+I*] Internal Buffer Data Print
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Print the stored data in the internal buffer.
[Format]
<I*>
[Coding Example]
<A>
<I*>
<Z>
 
No.
Item name
01
DATA1
02
DATA2
03
DATA3
04
.
.
.
.
.
.
16
[Supplementary Explanation]
-
Use this command in between Start Code <A> and Stop Code <Z>.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
Internal buffer
Number
Data contents
of digits
5
12345
5
12345
8
12345678
0
.
.
.
.
.
.
0
I*
<49>
<2A>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
Internal buffer
number
Internal Buffer Data Dump
# # 01 DATA1
31 32 33 34 35
Print result
# # 02 DATA2
31 32 33 34 35
# # 03 DATA3
31 32 33 34 35 36 37 38
384
Parameter
None
Item name
Number of
digits
(5)
(5)
(8)
Data contents