[ESC+J] Journal Print
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the print of journal.
[Format]
<J>a...a+CR
-
Parameter
a [Journal print column] = Print data
CR [Control code (0DH)]
[Coding Example]
<A>
<J>
ABCD+CR
EFGH+CR
<Z>
[Supplementary Explanation]
-
This command starts journal print from vertical position of 2 dots and horizontal position of 2
dots.
-
Character pitch is set to 2 dots and line pitch is set to 16 dots.
-
This command prints in 2 x 2 times of XS font.
-
Use of this command in combination with other commands is invalid. But, only Reprint <C> and
Reverse Color Print <(> are available.
-
This command performs the line feed regardless of setting of CR/LF deletion.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
J
<4A>
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
53
Parameter
a...a+CR<0D>
16