SATO SG112 ex Programming Reference Manual page 330

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+CE] European Code Page
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specify the European code page to be used.
[Format]
<CE>a...a(,b)
-
Parameter
a [Code page name] = Valid range : refer to the [Code page parameter] below.
b [Code page setting maintain] = Valid range :   P (fixed)
      Specify [P] to retain selected code page. (omissible)
      When omitted, the selected code page is not retained.
[Coding Example 1]
<A>
<V>100<H>200<P>2<L>0304<CE>1253<XU>ABCDE
<Q>2
<Z>
[Coding Example 2]
<A>
<V>100<H>200<P>2<L>0304<CE>855<XU>ABCDE
<Q>2
<Z>
[Code page parameter]
Parameter a
858
88591
88592
88599
850
852
855
857
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
Official name
DOS 858
Multilingual Latin 1 + Euro character
Default Code page proprietary to SATO.
ISO 8859/1
ISO 8859-1 Latin 1
ISO 8859/2
ISO 8859-2 Latin 2
ISO 8859/9
ISO 8859-9 Latin 5
DOS 850
Latin 1 Multilingual
DOS 852
Latin 2
DOS 855
Cyrillic
DOS 857
Turkish
CE
<43>
<45>
16
16
The set parameter is maintained.
The set command is valid until the next specification is
made.
The set command is valid until the next specification is
made.
Supplementary explanation
329
Parameter
a...a(,b)

Advertisement

Table of Contents
loading

Table of Contents