[ESC+_D] Variable Data
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying variable data for small labels.
[Format]
<_D>,aa,n...n
-
Parameter
a [Field numbrer] = Valid range 01 to 99
b [Variable data] = data*
* The digit number of the variable data should be equal to or less than the number specified by
Format <_N>. If it exceeds the specified length, the data will not be printed.
[Coding Example]
<A>
<A1>06363060<PD>,600,1020,0,0
<_F>
<_N>,01,04<V>100<H>200<L>0202<XM>0ABCD
<_N>,02,07<V>200<H>200<L>0202<B>103200*11111*
<_N>,03,02<V>100<H>800<L>0202<XM>022
<_D>,01,AAAA<_D>,02,*22222*<_D>,03,22<_Q>,1
<_D>,01,BBBB<_D>,02,*33333*<_D>,03,33<_Q>,2
<_D>,02,*44444*<_D>,03,44<_Q>,4   --------- (1)
<Z>
 
Print result
AAAA
BBBB
BBBB
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
22
BBBB
33
44
BBBB
44
44
_D
<5F>
<44>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
BBBB
33
BBBB
44
64