SATO SG112 ex Programming Reference Manual page 176

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

-
For print data of each barcode type, refer to the code tables of barcode.
[Notes]
-
If the value other than valid range is set, command error will occur and barcode will not be
printed.
-
A barcode that exceeds the printable area will not be printed.
-
Increasing narrow bar width may exceed the printing area and may not be printed.
-
Scanner may not read the barcode with valid character pitch when Character Pitch <P> is
increased. Also, increasing the narrow bar width may cause the same type of problem. For
more information, refer to the documentation of your scanner.
-
Set narrow bar width to 2 dots or more.
-
Adjust Print Speed <CS> or Print Darkness <#F> if there is a problem in barcode reading.
-
Matrix 2of5 will be expressed as Coop2of5/NEC2of5.
-
If Start/Stop character is not included in print data at the time of CODABAR(NW-7) or CODE39
specified, barcode will be printed; however, scanner cannot read it.
-
If sending the print data including check digit at the time of JAN/EAN-13 or JAN/EAN-8
specified, set the correct calculated value. Barcode will be printed even when the data includes
improper check digit; however, scanner cannot read it.