[ESC+BJ ESC+BJD] TrueType Font Registration (Compatible
command)
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying registration of TrueType Font.
[Format]
<BJ>(a...ab...b
<BJD>c ...cdddde...e
<BJ>)
-
Parameter
a [Font description] 40 byte font
b [Date]
c [Memory offset]
d [Number of data bytes]
e [Font data to download]
[Coding Example]
Font= 'abcdefghijabcdefghijabcdefghijabcdefghij' ,Date data=29-08-2010, Memory
offset=0000000220
<A>
<CC>1
<BJ>(abcdefghijabcdefghijabcdefghijabcdefghij29-08-2000
<BJD>00000002203001A00490020.....0000000
<BJ>)
<Z>
[Supplementary Explanation]
-
Specify the card slot number used for Card Slot <CC> prior to this command.
[Notes]
-
Do not power off this product when accessing to the memory. When this product is turned off
while memory accessing, the data in the accessed media may be corrupted.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
10 bytes date data
5 bytes memory offset (HEX)
Valid Range = 0001 to 9999
, Number of data bytes=3001, Font data= 'A00490020....00000000'
16
BJ
BJD
<42>
<4A>
16
16
<42>
<4A>
<44>
16
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.