SATO SG112 ex Programming Reference Manual page 322

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+PC] Designation of Registration on Printer Motion
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Registering the operation of this product.
[Format 1]
When setting all the items:
<PC>a,b,c,d,e,f,g,h,i,j,k,l,m,n,o,pppp,qqqq,rrrr,ssss,t,u,v,w,x,y,z,a1
-
Parameter
a     [Setting item number] = F: Setting for all the items
b...a1   [Setting content] = Refer to the table "Parameters" below.
[Format 2]
When setting specified item:
<PC>aa,b
-
Parameter
a    [Setting item No.] = Valid range: 1 to 26
b    [Setting content] = Refer to the table "Parameters" below.
[Coding Example 1]
setting all the items:
<A>
<PC>F,,,2,,,,,A,4,,1,0,,1,1,3000,2400,,,,,,,,,0
<Z>
[Coding Example 2]
setting specified item:
<A>
<PC>26,1
<Z>
[Supplementary Explanation]
-
Go to the Advanced Mode or Service Mode of the printer for setting.
-
Operation settings specified with this command are still in effect after turning off this product.
ESC
<1B>
16
Refer to the table "parameters" below.
When the power is OFF
Valid range within items
Valid range between items
PC
<50>
<43>
16
16
The set parameter is maintained.
The set parameter is valid until the next specification is
made.
The set parameter is valid until the next specification is
made.
321
Parameter
1: a,b,c,d,...,y,z,a1
2: aa,b

Advertisement

Table of Contents
loading

Table of Contents