[ESC+EP] Print End Position
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying the label stop position in the sensor ignored mode.
[Format]
<EP>
[Coding Example]
<A>
<A1>21361500
<Z>
<A>
<V>100<H>200<P>2<L>0202<XS>ABCD
<Q>2
<EP>
<Z>
Example)
[Supplementary Explanation]
-
Use this command in the sensor invalid mode.
-
Use this command in combination with Media Size <A1>.
-
If you specify Media Size <A1> in Format Registration <YS> and Form Overlay Registration
<&S> make sure to specify Print End Position <EP> when you specify Format Call <YR> and
Form Overlay Call <&R>.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
Stop position without the
command <EP >
ABCD
Stop position with the
command <E P>
EP
<45>
<50>
16
16
The set command is not maintained.
The set command becomes invalid.
The set command becomes invalid.
Base reference poi n t
1
1
125mm
1500dot
309
Parameter
None
178mm
2136dot