[ESC+KC] Kanji Code
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying Kanji Code.
Normally, the character code is specified in the user mode of the printer, however, the character
code can be changed temporary with this command <KC>.
[Format]
<KC>a
-
Parameter
a [Kanji code]
      0 : JIS code
      1 : Shift JIS code
      2 : Unicode
      4 : BIG5 code
      5 : GB18030 code
[Coding Example 1] In case of JIS code
<A>
<KC>0
<V>100<H>200<P>2<L>0202
<K1>H81698A94816A83548367815B
<Q>2
<Z>
[Coding Example 2] In case of Shift JIS code
<A>
<KC>1
<V>100<H>200<P>2<L>0202
<K1>H214A3374214B25352548213C
<Q>2
<Z>
[Coding Example 3] In case of Unicode
<A>
<KC>2
<V>100<H>200<P>2<L>0202
<K1>HFF08682AFF0930B530C830FC
<Q>2
<Z>
ESC
<1B>
16
a=0
When the power is OFF
Valid range within items
Valid range between items
KC
<4B>
<43>
16
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter becomes initial value at the next item
<A>.