[ESC+BS] USPS Barcode
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Printing USPS code.
[Format]
<BS>aabbbccccccddddddddd(e...e)
-
Parameter
a [Barcode ID] = Fixed 2 digits
       note: 0 to 4 should be specified for the 2nd digit.
b [Service Type ID] = Fixed 3 digits
c [Mailer ID] = Fixed 6 digits
d [Serial Number] = Fixed 9 digits
e [Routing Code] = Fixed 5 digits or fixed 9 digits or fixed 11 digits(can be omitted)
[Coding Example]
Barcode ID: 53, Service Type ID: 379, Customer Identifier: 777234, Serial Number: 994544928,
Routing Code: 51135759461
<A>
<V>100<H>200<BS>5337977723499454492851135759461
<Q>1
<Z>
[Supplementary Explanation]
-
For available parameter, refer to USPS code table in next page.
ESC
BS
<1B>
<42>
16
None
When the power is OFF
Valid range within items
Valid range between items
Parameter
<53>
aabbbccccccddddddddd(e...e)
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.