[ESC+GR] Graphic Call
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Invoking and printing out the data registered with Registration of Graphic <GI>.
[Format]
<GR>aaa
-
Parameter
a [Registration Number] = Valid range: 1 to 999
[Coding Example]
<A>
<V>100<H>100
<CC>1
<GR>1
<Q>1
<Z>
[Supplementary Explanation]
-
Specify slot number registered with Card Slot for Use <CC> prior to this command <GR> by all
means.
-
Ignoring Start Point Correction <A3> and making no correction.
-
Rotation <%> and Enlargement <L> are available for the invoked graphic.
-
Specify Card Slot for Use <CC> prior to this command when using.
-
The error occurs when specifying unused or specifying the slot which this product is allocated.
[Notes]
-
Do not power off this product when accessing to the memory. When this product is turned off
while memory accessing, the data in the accessed media may be corrupted.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
GR
<47>
<52>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.