[ESC+BC] CODE93 Barcode
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying CODE93 barcode.
[Format]
<BC>aabbbccn...n
-
Parameter
a [Narrow bar width] = Valid range : 01 to 12 dots
b [Height of Barcode] = Valid Range : 001 to 999 dots
c [Digit number of data] = Valid Range : 01 to 99
n [Print data] = Barcode data (Refer to the CODE93 – Code Table.)
[Coding Example]
Narrow bar width: 02, Barcode height: 120, Number of digit: 12, Print data: ABCD123456xy
<A>
<V>100<H>200<BC>0212012ABCD123456xy
<Q>2
<Z>
[Supplementary Explanation]
-
Check Digit is an auto-generation.
-
Start code and stop code will be automatically added.
-
Maximum entry digit number of data is 99.
-
[Digit number of data] and number of input data have to be equal.
-
Command error will occur when number of input data and [Digit number of data] are not
matched.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
BC
<42>
<43>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.