[ESC+RC] Sheet Unit Cut Quantity
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Specifying sheet cut quantity for small labels.
[Format]
<RC>aaaa
-
Parameter
a [Number] = Valid range: 0 to 9999
[Coding Example]
<A>
<RI>3200,1200,00,00,1600,0600,02,02
<A1>12003200
<RC>0001
<Z>
Cut position
[Supplementary Explanation]
-
The sheet is defined as an area specified by Media Size <A1>, if Label Size <RI> is used to
determine small label dimension.
[Points]
-
This command cannot be used in combination with other standard commands.
ESC
<1B>
16
a=0
When the power is OFF
Valid range within items
Valid range between items
RC
<52>
<43>
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
1st sheet
2nd sheet