SATO SG112 ex Programming Reference Manual page 346

Hide thumbs Also See for SG112 ex:
Table of Contents

Advertisement

[ESC+YR] Format Call
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Invoking and printing out the format registered with Registration of Format <YS>.
[Format]
<YR>,aaa
-
Parameter
a [Format registration Number] = Valid Range   :   1 to 999
[Coding Example]
<A>
<CC>1
<YR>,1
</D>,1,DEF
</D>,2,78901
</D>,3,49000238
<Q>2
<Z>
[Supplementary Explanation]
-
This command cannot invoke multiple formats between Start Code <A> and Stop Code <Z>.
-
Use this command and Print of Field </D> as a pair.
[Notes]
-
Do not power off this product when accessing to the memory. When this product is turned off
while memory accessing, the data in the accessed media may be corrupted.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
YR
<59>
<52>
16
16
The set parameter is not maintained.
The set parameter is valid until the next specification is
made.
The set parameter is valid until the next specification is
made.
345