IEEE1284
Basic Specifications
This interface complies with Centronics/IEEE1284 standard. Single item receive or multiple receive
can be switched on the interface mode of the printer.
Interface
Protocol
Status4, Status5
Refer to Communication protocol for details.
Connector
Product side: Amphenol 36 pin (Female)
Cable side: Amphenol 36 pin (Male)
Cable Length
Equal to or less than 1.5 m
Signal Level
High level: +2.4 to +5.0 V
Low level: +0.0 to +0.4V
Recieve Mode
Single item receive
Multiple buffer
buffer mode available by the interface mode of this product.
Receive Buffer Size
2.95 MB