[ESC+TW] Option Waiting Time
Hexadecimal code
Initial value
Valid range and term of
command
[Function]
Setting the option standby time.
[Format]
<TW>aaa
-
Parameter
aaa
[Waiting time] = Valid range   :   005 to 200 (unit: 100 ms)
[Coding Example] (waiting time = 1.5 seconds)
<A>
<TW>015
<Z>
[Supplementary Explanation]
-
This command specifies, in Tear-off mode, the waiting time between print completion and Tear-
off motion.
-
The set parameter becomes valid soon after receiving the command and will be retained after
power off.
ESC
<1B>
16
None
When the power is OFF
Valid range within items
Valid range between items
TW
<54>
<57>
16
16
The set parameter is maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
332