Timing chart of multiple receive
1) Normal process
Power On
Printer
SD
Initializing
XON
500 msec
RD
Printer Status
2) Error process
Head open
Printer
SD
STX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ETX (1)
RD
Printer Status
*
When the paper end error occurs, open the head, set label, close the head and feed.
Note: (1) The paper end error will be released when the head is closed.
(2) XOFF will be sent when data is received during an error.
XON
STX.ETX (2)
STX.ETX (1)
Receive/Analysis/Edit (1)
Receive/Analysis/Edit (2)
Note: The printer will be polled by ON at intervals of 500 msec from the initializing to the first data reception.
Head close
Press the LINE key
XOFF
XON
Offline
Receive/Analysis/Edit (1)
Receive buffer near full release
Receive buffer near full state
XOFF
XON
Online
Printing (1)
Paper end error
XOFF
STX . . . . . . . . . . . ETX (2)
Online
Receive/Analysis/Edit (2)
Printing (1)
459
Press the LINE key
XOFF
STX.ETX (3)
STX . . . . . . . . . . ETX (4)
Offline
Receive/Analysis/Edit (3)
Receive/Analysis/Edit (4)
Printing (2)
Press the LINE key
XON
XOFF
Offline
*
Press the LINE key
XON
Printing (3)
Printing (1)