For <DN> in Automatic setup, when 80H to 9FH and E0H to FFH is specified as data, it is
handed as Kanji mode, and cannot specify them as binary.
[Coding Example 1]
Error correction level: 7%, Size of one side of cell: 04
<A>
<V>100<H>200<2D32>,L,04,0
<DS>1,012345
<Q>2
<Z>
[Supplementary Explanation2]
-
If the parameter other than the description is specified or number of print data does not match,
printing is not performed.
-
Data specification command in data part varies according to parameter setup or specified data.
[Coding Example 2]
Error correction level: 7%, Size of one side of cell: 04, Mixed specification of Manual setup (Data
setup mode)
In Manual setup, you can proceed specifying data in specified input mode (Numeric, Alphanumeric,
Kanji, Binary).
<A>
<V>100<H>200
<2D32>,L,04,0
<DS>3, サトー
<DN>0010,0123456789
<DS>1,123
<Q>1
<Z>