Agilent Technologies ESA Series User's/Programmer's Reference page 108

Core spectrum analyzer functions
Hide thumbs Also See for ESA Series:
Table of Contents

Advertisement

Front-Panel Key Reference
Marker
Pressing
NOTE
position, so you can make delta measurements from differing reference
points without having to turn off the markers and begin again.
The delta marker function permits signal-to-noise measurements
NOTE
provided the signal is a single spectral component (sinusoid). Place a
normal marker on the signal, press
noise, and activate
difference is signal-to-noise/Hz.
Enters a mode that allows adjustment of both the
Delta Pair
(stop) markers independently. Pressing
Ref Delta
reference and delta markers. The start marker number is indicated
with a number and an R above the marker (for example, 1R) and the
delta marker is indicated with a marker number. This mode is useful in
functions such as
while in segmented sweep, refer to
Functions"
on
Key Access:
Ref and Delta markers maintain their displayed x-axis location, but not
NOTE
their frequency values when you change a parameter that redefines the
x-axis scale. Reset these markers when parameters such as Span or
Center Freq are changed.
Enters a mode that allows adjustment of both the ref and delta
Span Pair
markers. Pressing
Span Center
markers. The start marker number is indicated with a number and an R
above the marker (for example, 1R) and the stop marker is indicated
with a marker number. Adjusting the span changes the frequency
difference between the two markers while maintaining the midpoint
between the two markers at a fixed frequency. Changing the center
changes the center point between the two markers while maintaining
the frequency difference. This mode is useful in functions such as
Band Power
sweep, refer to
segmented sweep section of this chapter which begins on
on page
Span Pair is not available when
NOTE
selected.
Key Access:
108
again moves the reference marker to the active marker
Delta
Marker Noise
Band Power
in the segmented sweep section of this chapter which begins
"Segmented" on page
149.)
Marker
Span Pair
. (For information on using this function while in segmented
"Interaction with Other Analyzer Functions"
149.)
Marker
, place the delta marker in the
Delta
(see below). The indicated amplitude
, toggles between the
Delta Pair
. (For information on using this function
"Interaction with Other Analyzer
, toggles between the span and center
,
FREQUENCY
Scale Type (Log)
(start) and
Ref
Delta
in the
"Segmented"
is
Chapter 2