ABB IRB 760 Series Product Manual page 371

Hide thumbs Also See for IRB 760 Series:
Table of Contents

Advertisement

After calibration
1
2
3
Product manual - IRB 760
3HAC039838-001 Revision: M
5.4.4 Axis Calibration - Running the calibration procedure
Action
Check the o-ring on the fixed calibration pin.
Replace if damaged or missing.
Reinstall the protective cover on the fixed calibra-
tion pin on each axis, directly after the axis has
been calibrated.
Replace the cover with new spare part, if missing
or damaged.
Reinstall the protective plug and sealing in the
bushing on each axis, directly after the axis has
been calibrated. Ensure that the sealing is not
damaged.
Replace the plug and the sealing with new spare
part, if missing or damaged.
© Copyright 2011-2018 ABB. All rights reserved.
5 Calibration
Continued
Note
xx1600002102
Protection cover and plug set:
3HAC056806-001.
xx1500000952
Protection cover and plug set:
3HAC056806-001.
371

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 760-450/3.2

Table of Contents