ABB IRB 760 Series Product Manual page 175

Hide thumbs Also See for IRB 760 Series:
Table of Contents

Advertisement

Removing, brake release board
Use this procedure to remove the brake release board.
1
2
3
4
5
6
7
Product manual - IRB 760
3HAC039838-001 Revision: M
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before handling
the unit read the safety information in section
The unit is sensitive to ESD on page 31
Remove the push button guard from the SMB
cover.
Open the SMB cover by unscrewing the attach-
ment screws.
Let the battery stay connected, to avoid the
need of synchronization of the robot!
CAUTION
Clean cover from metal residues before
opening.
Metal residues can cause shortage on the
boards which can result in hazardous failures.
Take a picture or make notes of how the robot
cabling is positioned in regard to the brake
release board.
Remove the complete brake release board
(including brake release board and bracket)
from the SMB recess, by removing its two at-
tachment screws.
Disconnect the connectors X8, X9 and X10
from the brake release board.
© Copyright 2011-2018 ABB. All rights reserved.
4.3.4 Replacing the brake release board
Note
Shown in the figure
release board on page
The guard must be removed to ensure
a correct refitting of the brake release
board.
Shown in the figure
release board on page
X8
X9
xx1700000978
Location of the brake release unit is
shown in the figure
Location of brake
release board on page
Continues on next page
4 Repair
Continued
Location of brake
174.
Location of brake
174.
X10
174.
175

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: