3HAC039838-001 Revision: M
Action
Refit the bottom plate underneath the robot
base by pushing it into the groove and fitting
the attachment screw.
If removed, also refit the rear connector plate.
Note
Direct the bends on the bottom plate down-
wards!
CAUTION
The base and axis 1 gearbox weighs 130 kg
+ 200 kg.
All lifting accessories used must be sized ac-
cordingly!
Lift the robot base and gearbox 1 and remove
the base and gear support.
Secure the base to the mounting site.
Refit the complete arm system.
CAUTION
This is a complex task to be performed with
utmost care in order to avoid injury or dam-
age!
Perform a leak-down test.
Refill the gearbox with oil.
Recalibrate the robot.
© Copyright 2011-2018 ABB. All rights reserved.
4.7.1 Replacing the axis 1 gearbox
Note
1 screw: M6 x 8.
xx0300000612
A: Bottom plate
B: Rear connector plate
C: Attachment screw
D: Groove
See
Orienting and securing the robot
on page
75.
See
Replacing the base, including axis
1 gearbox on page
178.
See section
Performing a leak-down
test on page
146.
See
Changing oil, axis-1 gearbox on
page
126.
Pendulum Calibration is described in
Operating manual - Calibration Pendu-
lum, enclosed with the calibration tools.
Axis Calibration is described in
ing with Axis Calibration method on
page
360.
General calibration information is in-
cluded in section
Calibration on
page
349.
Continues on next page