Suzuki Ignis Service Manual page 1456

Rg413
Table of Contents

Advertisement

Troubleshooting
Step
1
Was "Automatic Transaxle Diagnostic Flow Table"
performed?
2
Do you have SUZUKI scan tool?
3
Check Transmission range sensor(switch) circuit
for operation.
Check by using SUZUKI scan tool:
1) Connect SUZUKI scan tool to DLC with ignition
switch OFF.
2) Turn ignition switch ON and check transmis-
sion range signal (P, R, N, D, 2 or L) on display
when shifting select lever to each range.
Is applicable range indicated?
Are check results satisfactory?
4
Check Transmission range sensor(switch) circuit
for operation.
Check by not using SUZUKI scan tool:
1) Turn ignition switch ON.
2) Check voltage at terminals "C38-1", "C38-7",
"C38-8", "C38-18", "C38-19" and "C38-20"
respectively with select lever shifted to each
range.
Taking terminal G99-21 as an example, is battery
voltage indicated only when select lever is shifted
to "2" range and 0 V for other ranges as shown in
table below?
Check voltage at other terminals likewise, referring
to Select Cable.
Are check results satisfactory?
5
Check transmission range sensor for installation
position.
1) Shift select lever to "N" range.
2) Check that "N" reference line on sensor and
needle direction shaped on lock washer are
aligned.
Are they aligned?
6
Check select cable for adjustment referring to
"Select Cable" in this section.
Is it adjusted correctly?
Action
Yes
Go to Step 2.
Go to Step 3.
Intermittent trouble.
Check for intermittent
referring to "Intermittent
and Poor Connection" in
Section 0A.
Intermittent trouble.
Check for intermittent
referring to "Intermittent
and Poor Connection" in
Section 0A.
Go to Step 7.
Go to Step 6.
AUTOMATIC TRANSAXLE 7B-51
No
Go to "Automatic Tran-
saxle Diagnostic Flow
Table" in this section.
Go to Step 4.
Go to Step 5.
Go to Step 5.
Adjust.
Adjust.

Advertisement

Table of Contents
loading

Table of Contents