Suzuki Ignis Service Manual page 1494

Rg413
Table of Contents

Advertisement

Con-
Terminal
Wire color
nector
number
1
BLK
2
LT GRN
3
4
BRN/YEL
5
WHT/BLU
6
YEL/BLK
7
WHT
8
9
10
11
BLU/RED
C39
12
GRY/RED
13
14
WHT/GRN
15
BLK/YEL
16
BRN
17
RED
18
19
20
21
22
23
BLK
24
WHT/RED
Circuit
Ground
Pressure control solenoid
valve (–)
Pressure control solenoid
valve (+)
TCC solenoid valve
Power source
CAN communication line
(Low)
Transmission fluid tem-
perature sensor (+)
Transmission fluid tem-
perature sensor (–)
Timing solenoid valve
Shift solenoid valve-B
(No.2)
Shift solenoid valve-A
(No.1)
CAN communication line
(High)
Ground
Power source for back-up
Normal
Voltage
0 – 1 V
Ignition switch ON
0.6 – 1.0 V
Ignition switch ON
0 – 0.6 V
↑↓
Engine running at idling.
10 – 14 V
(Output signal is duty pulse. Duty
(3. Reference
ratio varies depending on throttle
waveform
valve opening.)
No.3)
0 – 1 V
Engine running at idling speed.
10 – 14V
Ignition switch ON
2.5 – 3.6 V
Engine running at idling with after
↑↓
warming up.
1.6 – 2.5 V
(CAN communication signal is pulse.
(4. Reference
Pulse signal frequency varies
waveform
depending on engine condition.)
No.4)
Ignition switch ON, fluid temperature
2.9 – 3.1 V
is 20°C (68°F)
Ignition switch ON, fluid temperature
0.3 – 0.5 V
is 100°C (212°F)
0 – 1 V
Ignition switch ON
0 – 1 V
Ignition switch ON
Ignition switch ON, select lever in "P"
9 – 14 V
range
Ignition switch ON, select lever in "P"
9 – 14 V
range
2.5 – 3.6 V
Engine running at idling with after
↑↓
warming up.
1.6 – 2.5 V
(CAN communication signal is pulse.
(4. Reference
Pulse signal frequency varies
waveform
depending on engine condition.)
No.4)
0 – 1 V
Ignition switch ON
10 – 14 V
Constantly
AUTOMATIC TRANSAXLE 7B-89