Suzuki Ignis Service Manual page 1744

Rg413
Table of Contents

Advertisement

C-04, Control Unit Main Relay Circuit
Test Table (For RM413D)
Test
Work Order Description
T01
Check: Short to Ground/Interruption of Voltage Supply Circuit
• Ignition OFF
• Remove electrical component from socket:
Main Relay
• Measure voltage between the following terminals:
Main Relay – Socket Terminal E58-2
&
Ground
Yes: T02
T02
Check: Interruption of Voltage Supply Circuit
• Measure voltage between the following terminals:
Main Relay – Socket Terminal E58-1
&
Ground
Yes: T03
T03
Check: Short to Voltage of Voltage Supply Circuit
• Disconnect wiring harness connector from:
ECM
• Ignition ON
• Measure voltage between the following terminals:
Main Relay – Socket Terminal E58-4
&
Ground
Yes: T04
T04
Check: Short to Voltage of Signal Circuit
• Measure voltage between the following terminals:
Main Relay – Socket Terminal E58-3
&
Ground
Yes: T05
T05
Check: Interruption of Voltage Supply Circuit
• Ignition OFF
• Connect fused jumper wire to:
Main Relay – Socket Terminal E58-4
&
Battery positive (+) terminal
• Measure voltage between the following terminals:
ECM – Wiring harness connector (wiring harness side) terminal E27-6
&
Ground
Yes: T06
ENGINE GENERAL INFORMATION AND DIAGNOSIS (Z13DT ENGINE) 6-3-85
Nominal Value
greater than 11 V
No: T12
greater than 11 V
No: E10
less than 0.3 V
No: T11
less than 0.3 V
No: E07
greater than 11 V
No: E06