COMPULSORY VALVE OPERATION CHECK MODE
ENGINE (DIAGNOSTICS)
13.Compulsory Valve Operation
Check Mode
A: OPERATION
1) Prepare the Subaru Select Monitor kit. <Ref. to
EN(H4DOSTC)-8, PREPARATION TOOL, Gener-
al Description.>
2) Connect the diagnosis cable to Subaru Select
Monitor.
3) Insert the cartridge into Subaru Select Monitor.
<Ref. to EN(H4DOSTC)-8, PREPARATION TOOL,
General Description.>
4) Connect the test mode connector at the lower
portion of instrument panel (on the driver's side), to
the side of center console box.
5) Connect the Subaru Select Monitor to data link
connector.
EN-00038
ST
EN-00039
EN-01000
EN(H4DOSTC)-36
(1) Connect the Subaru Select Monitor to data
link connector located in the lower portion of the
instrument panel (on the driver's side).
(2) Connect the diagnosis cable to data link
connector.
CAUTION:
Do not connect scan tools except for the
Subaru Select Monitor and OBD-II general scan
tool.
6) Turn the ignition switch to ON (engine OFF) and
Subaru Select Monitor switch to ON.
(A) Power switch
7) On the «Main Menu» display screen, select the
{2. Each System Check} and press [YES] key.
8) On the «System Selection Menu» display
screen, select the {Engine Control System} and
press [YES] key.
9) Press the [YES] key after displayed the informa-
tion of engine type.
10) On the «Engine Diagnosis» display screen, se-
lect the {System Operation Check Mode} and press
[YES] key.
11) On the «System Operation Check Mode» dis-
play screen, select the {Actuator ON/OFF Opera-
tion} and press [YES] key.
12) Select the desired compulsory actuator on the
«Actuator ON/OFF Operation» display screen and
press [YES] key.
EN-00999
( A )
EN-00040