CLEAR MEMORY MODE
ENGINE (DIAGNOSTICS)
12.Clear Memory Mode
A: OPERATION
1. SUBARU SELECT MONITOR (NORMAL
MODE)
1) On the «Main Menu» display screen, select the
{2. Each System Check} and press [YES] key.
2) On the «System Selection Menu» display
screen, select the {Engine Control System} and
press [YES] key.
3) Press the [YES] key after displayed the informa-
tion of engine type.
4) On the «Engine Diagnosis» display screen, se-
lect the {Clear Memory} and press [YES] key.
5) When the 'Done' and 'Turn Ignition Switch OFF'
are shown on the display screen, turn the Subaru
Select Monitor and ignition switch to OFF.
NOTE:
• For detailed operation procedure, refer to the
SUBARU SELECT MONITOR OPERATION MAN-
UAL.
2. SUBARU SELECT MONITOR (OBD
MODE)
1) On the «Main Menu» display screen, select the
{2. Each System Check} and press [YES] key.
2) On the «System Selection Menu» display
screen, select the {Engine Control System} and
press [YES] key.
3) Press the [YES] key after displayed the informa-
tion of engine type.
4) On the «Engine Diagnosis» display screen, se-
lect the {OBD System} and press [YES] key.
5) On the «OBD Menu» display screen, select the
{4. Diagnosis Code(s) Cleared} and press [YES]
key.
6) When the 'Clear Diagnostic Code?' is shown on
the display screen, press [YES] key.
7) Turn the Subaru Select Monitor and ignition
switch to OFF.
NOTE:
• For detailed operation procedure, refer to the
SUBARU SELECT MONITOR OPERATION MAN-
UAL.