Bri-Set, Asai-Adj, Bri-Dat - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures

BRI-SET, ASAI-ADJ, BRI-DAT

MO's Name As It
Appears in
Alarm Log
Alarm Level
BRI-SET
WARNING
BRI-DAT
ASAI-ADJ
MAJOR
ASAI-ADJ
MAJOR
ASAI-ADJ
WARNING
ATT-ADJ
MAJOR
ATT-ADJ
MAJOR
ATT-ADJ
WARNING
LGATE-AJ
MAJOR
LGATE-AJ
MAJOR
LGATE-AJ
WARNING
ATTE-AJ
MAJOR
ATTE-AJ
MAJOR
ATTE-AJ
WARNING
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21). pp is the 2-digit port number
(01, 02,...).
2.
The alarm level for ASAI and Avaya adjuncts may be administered using the set options command. The alarm
level can be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for every ASAI
and Avaya adjunct in the system.
3.
Alarming for an ASAI and Avaya adjuncts is disabled if the adjunct asks the switch to suspend maintenance.
When this occurs, an error and a WARNING alarm are logged against the endpoint. Busying out and releasing
the ASAI station or ADJLK station will clear the alarm.
!
WARNING:
''Isolating and Repairing Packet-Bus Faults''
resolving packet-bus faults is included in
Troubleshooting''. The flowchart
Problems along with the other information presented in the chapter, can help
resolve problems that involve more than a single station or circuit pack. See
also
''Maintenance of the Packet Bus'' on page 4-87
!
WARNING:
If a significant packet-bus failure occurs, errors and alarms may not be
logged as expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/
ATTE-PT. Conditions under which this occurs are detailed in the
''Maintenance of the Packet Bus''
Troubleshooting''.
8-354
Issue 1 May 2002
Initial Command to Run
2
test station extension l
test data-module extension
2
)
test station extension
2
test data-module extension
3
test data-module extension
2
test station extension
2
test station extension
3
test station extension
2
test station extension
2
test station extension
3
test station extension
2
test station extension
2
test station extension
3
test station extension
Figure
1
Full Name of MO
ISDN-BRI Set
ASAI-Adjunct
ASAI-Adjunct
ASAI-Adjunct
Avaya-Adjunct
Avaya-Adjunct
Avaya-Adjunct
Ethernet ASAI-Adjunct
Ethernet ASAI-Adjunct
Ethernet ASAI-Adjunct
Ethernet Avaya-Adjunct
Ethernet Avaya-Adjunct
Ethernet Avaya-Adjunct
information for isolating and
Chapter 4, ''Alarms, Errors, and
4-45, Troubleshooting Packet Bus
section of
Chapter 4, ''Alarms, Errors, and
555-233-143

Advertisement