up the code window. The following is the description of the subprograms
associated with the respective buttons.
Procedure called when the user clicks the Copy button on the UserForm
(lines 10 to 520)
Lines 90 to 160
These lines identify the selected items in each list and store them into the
variables TrGet, TrPut, and ActCh.
Lines 180 to 210
If the specified target trace is not displayed, these lines display that trace.
Lines 230 to 250
These lines make active the specified trace (TrGet: source trace) in the
specified channel(ActCh) and hold the sweep.
Line 260
Reads the number of measurement points for the specified channel (ActCh)
and stores that number into the Nop variable.
Line 280
Reads the formatted data array for the active trace (source trace) and
store the data into the FmtData variable.
Line 290
Reads the stimulus array for the specified channel (ActCh) and stores the
data into the Freq variable.
Line 330
Reads the data format for the active trace (source trace) and store it into
the Fmt variable.
Lines 340 to 350
These lines display the echo window in the lower part of the LCD screen.
Lines 360 to 470
The lines display, in the echo window, each point along with one measured
value (the odd part of the index is always 0) and a frequency if the Fmt is
"MLOG", "PHAS", "GDEL", "MLIN", "SWR", "REAL", "IMAG", or "UPH"; or
Programming