Agilent Technologies E5071C Manual page 1358

Hide thumbs Also See for E5071C:
Table of Contents

Advertisement

SCPI.CALCulate(Ch).FSIMulator.BALun.DZConversion.BPORt(Bpt).Z0.R
Object type
Property (Read-Write)
Syntax
SCPI.CALCulate(Ch).FSIMulator.BALun.DZConversion.BPORt(Bpt).Z0.R =
Value
Value =
SCPI.CALCulate(Ch).FSIMulator.BALun.DZConversion.BPORt(Bpt).Z0.R
Description
This command sets/gets the impedance value for the differential port
impedance conversion function, for the balance ports 1 and 2 (Bpt) of
selected channel (Ch).
This command clears setting value of
"SCPI.CALCulate(Ch).FSIMula-tor.BALun.DZConversion.
BPORt(Bpt).IMAGinary"
Variable
Parameter
Description
Data type
Range
Preset
value
Unit
Resolution
Note
Examples
Value
Impedance value for the differential port impedance
conversion function
Double precision floating point type (Double)
1E-3 to 1E7
100
ohm
0.001
If the specified variable is out of the allowable setup
range, the minimum value (if the lower limit of the
range is not reached) or the maximum value (if the
upper limit of the range is exceeded) is set.
Programming