Dim DmcG As Double
SCPI.CALCulate(1).FSIMulator.BALun.DMCircuit.BPORt(1).PARameters.G = 12E-12
DmcG = SCPI.CALCulate(1).FSIMulator.BALun.DMCircuit.BPORt(1).PARameters.G
Related objects
SCPI.CALCulate(Ch).FSIMulator.BALun.DMCircuit.BPORt(Bpt).PARameters.
C
SCPI.CALCulate(Ch).FSIMulator.BALun.DMCircuit.BPORt(Bpt).PARameters.
L
SCPI.CALCulate(Ch).FSIMulator.BALun.DMCircuit.BPORt(Bpt).PARameters.
R
SCPI.CALCulate(Ch).FSIMulator.BALun.DMCircuit.BPORt(Bpt).TYPE
SCPI.CALCulate(Ch).FSIMulator.BALun.DMCircuit.STATe
Equivalent key
> Fixture Simulator > Diff Matching > G
Analysis
Equivalent SCPI command
Syntax
:CALCulate{[1]-160}:FSIMulator:BALun:DMCircuit:BPORt{[1]|2}
:PARameters:G <numeric>
:CALCulate{[1]-160}:FSIMulator:BALun:DMCircuit:BPORt{[1]|2}
:PARameters:G?
Query response
{numeric}<newline><^END>
Example of use
10 OUTPUT 717;":CALC1:FSIM:BAL:DMC:BPOR1:PAR:G 12.3"
20 OUTPUT 717;":CALC1:FSIM:BAL:DMC:BPOR1:PAR:G?"
30 ENTER 717;A