SCPI.CALCulate(Ch).FSIMulator.BALun.PARameter.TNAMe.BBALanced.DEFi
ne(Name)
Object type
Property (Read-Write)
Syntax
SCPI.CALCulate(Ch).FSIMulator.BALun.PARameter.TNAMe.BBALanced.DEFi
ne(Name) = Param
Param =
SCPI.CALCulate(Ch).FSIMulator.BALun.PARameter.TNAMe.BBALanced.DEFi
ne(Name)
Description
This command sets/gets the measurement parameter when the balance
device type is "balance-balance", for the selected channel (Ch). The trace
can be selected by the trace name once its defined earlier with
SCPI.CALCulate(Ch).PARameter(Tr).TNAMe.DATA command. This function
is available in the revision A.9.60 and above.
Variable
Parameter
Description
Data type
Parameter
Description
Data type
Range
1592
Name
Trace Name
Character string type (String)
Param
Measurement parameter
Character string type (String)
Select from the following.
"SDD11": Specifies
Sdd11.
"SDD21": Specifies
Sdd21.
"SDD12": Specifies

Hide quick links: