UNIVERGE SV8100
Program
Number
80-04-03
80-04-04
80-04-05
80-04-06
80-04-07
Voice Mail Integration (Analog)
Program Name
Call Progress Tone Detector
Setup – S/N Ratio
Call Progress Tone Detector
Setup – No Tone Time
Call Progress Tone Detector
Setup – Pulse Count
Call Progress Tone Detector
Setup – ON minimum time
Call Progress Tone Detector
Setup – ON maximum time
Description/Comments
Use to define the S/N ratio for the
Call Progress Tone Detector.
Use to define the no tone time for
the Call Progress Tone Detector.
Use to define the pulse count for
the Call Progress Tone Detector.
Use to define the on minimum time
for the Call Progress Tone
Detector.
Use to define the on maximum
time for the Call Progress Tone
Detector.
Issue 5.0
Assigned Data
0~4 (0dB ~ -20dB)
default:
Type 1 (DT) – 4
(-20dB)
Type 2 (BT) – 4
(-20dB)
Type 3 (RBT) – 4
(-20dB)
Type 4, Type 5 – 0
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 132
(3990ms)
Type 2 (BT) – 132
(3990ms)
Type 3 (RBT) – 132
(3990ms)
Type 4, Type 5 – 0
1~255
default:
Type 1 (DT) – 1
Type 2 (BT) – 1
Type 3 (RBT) – 1
Type 4, Type 5 – 0
1~255 (30+30-
7680ms)
default:
Type 1 (DT) – 63
(1920ms)
Type 2 (BT) – 12
(390ms)
Type 3 (RBT) – 25
(780ms)
Type 4, Type 5 – 0
0~255 (30+30-
7680ms)
default:
Type 1 (DT) – 0
Type 2 (BT) – 20
(630ms) [ET]
Type 3 (RBT) – 40
1230ms)
Type 4, Type 5 – 0
1 - 1101