System message for DtermIP (SIP)/Soft Phone (SIP) is as follows.
Note:
SYSTEM MESSAGE 36-N IP Equipment Status Report
Main Office LTS May 18 13:12
LP08-0-ACT
Header
1: 6020 0100 820A 29CF 2:C900 0000 0003 0200 3:0000 0000 0000 0000
[1]
[2]
4: 0000 0000 0000 0000 5:0000 0000 0000 0000 6:0000 0000 0000 0000
[9]
7: 0000 0000 0000 0000 8:0000 0000 0000 0000 9:0000 0000 0000 0000
[1]: Accommodation Location (Line Equipment Numbers)
Accommodation Location for each equipment is obtained as shown below:
0x60
0x20
0x01
0x00
0x60
0x20
0x01
0x00
0x60
0x20
0x01
0x00
Thus, Module Group = 8, Unit = 0, Group = 12, Level = 0 are obtained in this instance.
[3]
[19]
b7
b6
b5
b4
b3
GROUP
Module Group
0
FPC
NOP
Convert the value indicated in hexadecimal to binary.
b7
b6
b5
b4
b3
0
1
0
1
0
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
Read the value in decimal on a category basis.
Group = 12
MG = 8
0
FPC = 1
NOP = 0
– 173 –
CHAPTER 2
[20]
[21]
b2
b1
b0
LEVEL
UNIT
b2
b1
b0
0
0
0
0
0
0
1
0
0
0
0
0
LV = 0
U = 0
Operations of SV8500 Server