NEC Univerge SV8500 Operation And Maintenance Manual page 761

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

(b) NODE that SOFTVER is different exists.
As a result of the data readout, the different SOFTVER (ROM)s coexist in the same network. FPC of
the corresponding node is not indicated because it is impossible to determine which SOFT-
VER(ROM) is correct. While this message is displayed, "Del." button is invalid.
(c) NODE to which SOFTVER can't be read exists.(FPC: XXX)
Program version information of a node cannot be read out due to FCCS link disconnection, etc. FPC
of the corresponding node is indicated. If multiple nodes apply, the smallest FPC in the corresponding
nodes is displayed.
(d) CPU Faction to which SOFTVER can't be read exists. (FPC: XXX)
Program version information of a node cannot be read out due to power failure of one of the CPUs
(CPU#0/CPU#1), etc. FPC of the corresponding node is indicated. If multiple nodes apply, the small-
est FPC of the corresponding nodes is indicated.
Buttons
Get:
By pressing this button, the following output data appears.
Note 4:
If program version data has been assigned to NDM, the assigned program version is displayed in
Note 5:
SOFTVER (NDM) parameter and "Del." button will be active.
If no program version data has been assigned, the earliest program version in the FCCS network is
displayed in SOFTVER (NDM) parameter and "Set" button will be active.
Set:
To change the program version data written in NDM, delete it first, and then assign the new version
Note 6:
data.
Del.:
Exit:
Output Data
FPC:
CPU:
SOFTVER (SYSTEM): The currently enabled program version of each node (in hexadecimal). Note 8
When no program version data has been assigned to NDM and each node operates without the restric-
Note 7:
tion of the program version data, "NO Action Limit" is displayed.
When program version data has been assigned to NDM and each node operates with the restriction of
the program version data, the assigned program version data is displayed. "No Action Limit" or the
program version data is displayed only for ACT-CPU. "-----" is displayed for STBY-CPU.
Read out the information. This button is always operative. Note 4, Note 5
Set the program version data displayed in SOFTVER (NDM) parameter. Note 6
Delete the program version data written in NDM.
Exit this command. This button is always operative.
Fusion Point Code of each node.
CPU (CPU#0/CPU#1) of each node.
CHAPTER 7
– 714 –
Maintenance Commands

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp85-104 s1e

Table of Contents