NEC Univerge SV8500 Operation And Maintenance Manual page 511

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

3
4
FNC( )
INF( )
05
04
07
06
07
08
08/102
09
01
Table 3-2 Troubleshooting For Fault Information
5
FLT( )
02
This message is output when the connection cannot establish between
Telephony Server and IP terminals.
The cause could be considered that related equipment are abnormal.
Make sure that the MG with the MAC address shown on the message is
available to use. If it is listed as available, keep watching it. Otherwise,
contact NEC engineers.
02
If this message is frequently output, review the network and make sure
the LAN configuration, or ask maintenance personnel.
01
If this message is frequently output, replace the appropriate MG.
02
03
04
05
ALL
If this message is frequently output, review the network and make sure
the LAN configuration, or ask maintenance personnel.
6
9
01
-
: Socket number acquired
6
:
02
Recovery Detail
01: Recovered from socket fault
02: Recovered from data transmission error
6
03
: FPC number of adjacent nodes which has recovered
7 10
-
: IP Address of adjacent nodes which has recovered
– 464 –
CHAPTER 3
System Messages
SOLUTION

Hide quick links: