A Both Tsw Failure (Permanent) - NEC Univerge SV8500 Operation And Maintenance Manual

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

1-A: Both TSW Failure (Permanent)
Default Alarm
MN
This message displays when link information cannot be written into the switch memory of the TSW in both
systems.
1: XXXX XXXX XXXX XXXX 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
1
2
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
1
TSW system in which a fault is
detected
b7
2
Status at the time of fault detection
b7
b6
3
Data Analyzed by NEC Engineers
Reference: See
section 4.5.3 on page
Default Grade
3
3
b0:
0/1 = TSW 0/TSW 1
b0
b0:
0/1 = TSW System 0/TSW System 1
b6:
Speech Path in ACT status
b0
0/1 = System 0/System 1
633, for the repair procedure.
Grade Modified
– 217 –
CHAPTER 3
System Messages
Lamp Modified