3-L: Line Fault Release
Default Alarm
SUP
This message indicates that A wire and B wire of the line between the LC circuit card and telephone set, which
once short-circuited (cf. 3-K "Line Fault" (Page 240)), have become normal.)
This message is available in Australia only.
Note:
1: XX0X 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
1 2
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
1
Location of the faulty line (G, U, MG No.)
b7
b6 b5 b4
b3
2
Location of the faulty line (level number)
b7
Default Grade
1
b2
b1
b0
b0-b4: Group number
b5, b6: Unit (0-3)
b7:
b2
b1
b0
b0-b2: Level Number (0-7)
Grade Modified
Module Group
0/1 = Even-numbered MG/Odd-numbered MG