The relationship of operation types and Initialization types is as follows.
Relationship between Initialization Types and Available Operations
Initialization Type
Non Load Initial
Office Data Load Initial
Office Data Load & Program Load Initial
Office Data Load & Program Load (& OS Load) Initial
CF Card
Program
(Main Memory)
Office Data
3.2 Initialization by PCPro (SINZ)
All initialization types shown below are available.
•
Non Load Initial
•
Office Data Load Initial
•
Office Data Load & Program Load Initial
•
Office Data Load & Program Load (& OS Load) Initial
Use shutdown option on SINZ command.
Note:
STEP 1
Execute SINZ from the PCPro.
STEP 2
Select an appropriate initialization type, and then click "Execute" button.
•
Initialization starts.
•
PCPro is automatically placed in logout state.
Figure 2-2 Office Data Load and Program Load
- Basic Software
- Service Software
- IMAT Software
- TCP/IP Software
- Data Memory
- Call Forwarding Data
- Speed Calling Data
- Name Display Data
etc.
CHAPTER 2
Available Operations
PCPro
PCPro
INIT key Operation
(SINZ)
Tools
X
-
X
-
X
-
X
X
Program Loading
Office Data Loading
Note
– 48 –
Operations of SV8500 Server
X: Available -: Not Available
Tuning Off/On
(EMA card)
X
-
-
-
MEM
- Program
- Office Data
Initialization
-
-
-
X