The operation changeover between SV8500 MGC and SR-MGC is manually executed. Select the operation
mode in Kind and Condition parameters, then click the Execute button. A dialog appears to confirm the
changeover execution.
Kind:
Select either of the operations by radio button.
All
Changeover to all the SR-MGCs in the network is executed.
Individual SR300 No.
Changeover to a specified SR-MGC is executed. Enter the SR-MGC Number (0~255) of the target SR-
MGC.
Condition:
Select the direction of the operation changeover for SR-MGC. This command is executed in the MGC side.
SR-MGC
MGC
Turns the SR-MGC to operation mode, which allows terminals to register to the SR-MGC.
SR-MGC
MGC
Turns the SR-MGC to stand-by mode, which does not allow terminals to register to the SR-MGC. Use
this parameter to switch into stand-by mode after "MGC
SYS1 INDEX852 Bit=0) is executed.
This parameter forcibly switches SR-MGC into operation mode from stand-by mode, which means SR-
Note 1:
MGC allows terminals to register to SR-MGC. This parameter does not help all the terminals regis-
tered in MGC to switch to SR-MGC.
After the mode of SR-MGC has been switched by this command, the SR-MGC will stay in operation
Note 2:
mode. To switch the SR-MGC into stand-by mode, use "SR-MGC
command. Note that the ASYDL setting (ASYDL SYS1 INDEX852 Bit 5) is not valid to these operations.
When SR-MGC enters stand-by mode, the MGC starts to operate.
<Office Data Copy Tab>
Manual Copy:
Select either of the radio buttons, Specifying SR-MGC or All SR-MGC (en bloc specifying) to execute of-
fice data copy manually.
Specifying SR-MGC
Click the Execute button after specifying the target SR-MGC number (0-255).
All SR-MGC (en bloc specifying)
Click the Execute button to execute office data copy to all the SR-MGCs in the network. Note 1
The meaning of the indication is:
Note 1:
Gray = SR-MGC Number is not accommodated
CHAPTER 7
SR-MGC" or manual changeover (ASYDL
Note 2
– 743 –
Maintenance Commands
Note 1
MGC" of Condition in the CMNT