D Sp Failure - NEC Univerge SV8500 Operation And Maintenance Manual

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

35-D: SP Failure
Default Alarm
MN
This message displays when any failure has influence on carrying on calls occur on SP.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
1
2
3
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
1
Accommodated location of fault-
detected SP or the PH under the
control of SP
b7
b6 b5 b4
b3
2
Type of failure (FNC)
b7
b6 b5 b4
b3
3
Failure information (INF)
b7
b6 b5 b4
b3
Default Grade
3
b0-b4: Group (G) No.
b5, b6: Unit (U) No.
b7:
b2
b1
b0
01H: Health check error
b2
b1
b0
When
b2
b1
b0
Grade Modified
Module Group (MG) No.
0/1 = Even-numbered MG/Odd-numbered MG
= 01 Hex:
01H: MPH failure
02H: PH failure
– 479 –
CHAPTER 3
System Messages
Lamp Modified