26-W: LAN Interface Release Report
Default Alarm
NON
This message displays when the LAN Interface Connection Failure, detected in System Message [26-V],
recovers. The message displays when the LAN Interface Connection Failure is restored. The first data is
normally sent/received by the recovered application equipment.
TCP/IP
1: XXXX XXXX XXXX 00XX 2: XXXX XX00 0000 0000 3: 0000 0000 0000 0000
1 2
3 4
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
4
1
-
IP Address for external equipment in which error has been detected. (HEX)
b7
b6
b5
b4
b3
6
5
,
Socket number (Used Socket number) (HEX) - Socket Number used by application whose failure has been
received.
b7
b6
b5
b4
b3
7
Error Code (TCP/IP Error Code) (HEX)See Table 3-1.
b7
b6
b5
b4
b3
Application Type
8
b7
b6
b5
b4
b3
Default Grade
7
5 6
8 9
b2
b1
b0
b2
b1
b0
b2
b1
b0
b2
b1
b0
Grade Modified
Application
10
b0-b7:
(HEX)
01=SUPER SERVER
02=MAT
03=SMDR
04=MCI
05=OAI
06=PMS
07=MIS
08=NMS
09=CS Report
– 435 –