NEC Univerge SV8500 Operation And Maintenance Manual page 221

Hide thumbs Also See for Univerge SV8500:
Table of Contents

Advertisement

[2]: Sequence Number and Fault Log Output Kind
Sequence Number (Bit0-6) = 0x01 (Sequence Number1)/0x02 (Sequence Number2)
Fault Log Output Kind (Bit7): 0/1 = Period/at the moment after registry
[3]: IP Address
Convert the value to decimal on a byte basis to obtain IP Address.
0x0A29CFC9 =10.41.207.201
[4]: Fault Log: 0x01
This data and the following data ([5] to [19]) are variable.
[5]: Data Length: (0034HEX) Variable
[6]: Data Kind
0x01/0x02/0x03 = Reset Factor/Control PKT Send/Receive Information/Registry NG Factor
[7]: Data Length
0x0E/0x1E/0x2E = Reset Factor/Control PKT Send/Receive Information/Registry NG Factor
[8]: The Number of Fault Logs
0x01 - 0x08
[9]: NOP: 0x00
[10]: Reset Factor
Major Item (0x09: Configuration Mode End)
Intermediate Item (0x01)
Minor Item (0x00)
Details (0x00)
[11]: Reset Execution Time: 2004/5/18 13:23 56.58 (Year/Month/Day Hour:Minute Second)
Reset Factor and Reset Execution Time are as follows:
0901 0000 2004 0518 1323 5658
Reset Execution Time
Details
Minor Item
Intermediate Item
Major Item