13-D: CCH Lock-Up Failure (Permanent)
Default Alarm
SUP
This message displays when a Port Microprocessor (PM) of the CCH/DCH card did not send an answer to the
.
CPU
1: XX00 0000 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
1
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
1
Location of faulty CCH/DCH card
b7
b6 b5 b4
b3
Default Grade
3
b0-b4: Group number
b5, b6: Unit (0-3)
b2
b1
b0
b7:
Grade Modified
0/1 = Even-numbered MG/Odd-numbered MG
– 374 –