0-H: B1-Level Infinite Loop (Temporary)
Default Alarm
SUP
This message displays when, in the CPU program processing, the counter value to check the normality of the
processing has become abnormal.
1: XXXX XX00 0000 0000 2: 0000 0000 0000 0000 3: 0000 0000 0000 0000
3
1
2
4: 0000 0000 0000 0000 5: 0000 0000 0000 0000 6: 0000 0000 0000 0000
7: 0000 0000 0000 0000 8: 0000 0000 0000 0000 9: 0000 0000 0000 0000
1
Self-CPU Restart Information
b7
b5 b4
b3
2
Mate-CPU Restart Information
(FF H: not mounted)
b7
b5 b4
b3
3
b7
Default Grade
1
b0:
0/1 = -/Monitor Restart
b3:
0/1 = -/Initialization
b0
b4:
0/1 = -/Data Copy restart (for Dual-CPU system only)
b5:
0/1 = -/MB control
b7:
0/1 = ACT/STBY (active system indication after restart)
b0:
0/1 = -/Monitor Restart
b3:
0/1 = -/Initialization
b4:
0/1 = -/Data Copy restart (for Dual-CPU system only)
b0
b5:
0/1 = -/MB control
b7:
0/1 = ACT/STBY (active system indication after restart)
b0:
0/1 = -/B-Level Infinite Loop
b1:
0/1 = -/Task Timer Timeout
b1
b0